Description
ES150 laser power supply is used for 150W CO2 laser gas discharge tubes
The power supplies are designed based on soft-switching zero-current half-bridge circuit, providing high efficiency and fast equipment, easy port control, high and low signal levels applied. The laser on/off is controlled by TTL logic (bipolar transistors are used), and the power supply is equipped with a safety switch to control the flow of water, air, etc. into the installation.
Main features of EFR power supply:
1. Good compatibility: The ES150 power supply is specially designed for 130W and 150W EFR laser tubes. Ordinary 130W and 150W laser tubes from other factories can also be used.
2. High voltage power supply: input voltage 220V or 110V AC, maximum output current 50KV.
3. You can choose the type of cutting or engraving; The cutting type has good energy stability and high adaptability; Sculpring Type has fast response speed and good engraving effect.
4. This power supply has a “TEST” button, which can manually test the output laser.
Benefits:
1. Easy control: laser start and stop can be easily controlled by TTL level. 0-5V analog signal and PWM signal can control laser power.
2. The power supply of the laser has protection against open circuit at the output. When the ground is in good condition, the power can be short-term in the open state, it can avoid damage to the laser tube caused by the laser power supply, prolong the life of EFR laser tubes.
3. This laser power supply has TTL signal indication, water through signal indication and laser output indication.
4. The power supply has a feedback interface, can be used for feedback control, can also be used to test the working current of the laser tube.
5. It can quickly determine whether the laser tube is damaged or the laser power supply is damaged, which greatly facilitates on-site maintenance.
All products pass ISO9001 and CE quality certification
Aging testing is carried out at the manufacturer’s factory . Each power supply undergoes pre-sales aging testing at 65°C under full load conditions for 10 hours and cycled on/off 300 times within 7 seconds
Model p> | ES150 / ES150A – with integrated ammeter |
Rated power of laser tube, W | 150 /you can also use regular laser tubes with power 130 and 150W/ |
Input voltage | 220/110V |
AC supply frequency | 47-440 Hz |
Maximum input current | 10A |
Maximum input power | 1000W |
Leakage current | ≤0.7mA (AC220V) ≤0.4mA (AC110V) |
Maximum output voltage | DC 50 kV |
Maximum output current | DC 38 mA |
Efficiency | 90% |
Responsiveness/Performance | less than 1 ms |
Protection | momentary shutdown (when there is a good ground) |
Voltage resistance | in-out, in-body: AC1500V 1min ≤10mA |
Cooling | forced, air (built-in fan)< /td> |
Operating temperature, deg | -10 ℃~ +40 ℃ |
Relative humidity | up to 90% (non-condensing) |
Time Between Failures (MTBF) | at least 10000 hours |
Dimensions L/W/H | 342 / 138 / 105 mm |
Reviews